Question:
Here is a general question, I am planning a project and will eventually get all proper permits but I want some advice to determine if this step is necessary

I am planning to install a steam room in a new bathroom and it requires a
35A, 220V dedicated breaker. My house has a 100A service panel with one 50A to the range, one 35A to the drier and about a dozen 20A wall plug circuits.


The question is: Is it likly that I will need to simultaniously upgrade the service panel to 150A when adding this circuit? What is the rule about the maximum capacity of a service panel?


Answer:
If air-conditioning equipments or electric space-heating equipments are to be installed, the following

formula shall be applied to determine if the existing service is of sufficient size.


Air-conditioning equipment* 100%


Central electric space heating* 100%


Less than four separately controlled space-heating units* 100%


First 8 kVA of all other loads 100%


Remainder of all other loads 40%